ACCURACY OF INTRAOPERATIVE RADIONUCLIDE SCINTIGRAPHY FOR DETECTION OF SENTINEL LYMPH NODE USING 99MTC LABELED NANOCOLLOIDS IN EARLY BREAST CARCINOMA

Intraoperative Radionuclide Scintigraphy

Authors

  • Zaigham Salim Dar Armed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
  • Omer bin Abdul Aziz Combined Military Hospital Kohat/National University of Medical Sciences (NUMS) Pakistan
  • Tanveer Sajid Combined Military Hospital Quetta/National University of Medical Sciences (NUMS) Pakistan
  • Mujahid Khalid Ali Armed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi Pakistan

Keywords:

Carcinoma Breast, Sentinel lymph node, 99mTc-Nanocolloids

Abstract

Objective: To determine the accuracy of intraoperative radionuclide scintigraphy for detection of sentinel lymph
node (SLN), using 99mTc-Nanocolloids, in patients with early breast carcinoma.
Study Design: Cross sectional analytical study.
Place and Duration of Study: Nuclear Medical Centre, Armed Forces Institute of Pathology, Rawalpindi and
department of Surgery, Pak Emirates Military Hospital, Rawalpindi, from Jul 2012 to Jun 2013.
Patients and Methods: After fulfilling the inclusion and exclusion criteria and taking written informed consent,
67 patients of carcinoma breast were enrolled in the study. Each patient was injected with 37 MBq of 99mTc-
Nanocolloids, via sub areolar, peri-tumoural route, pre-operatively. SLNs were identified using handheld gamma
probe followed by excision biopsy. Patients, then, underwent modified radical mastectomy with dissection of
axillary lymph nodes (ALN) and the samples were sent for histopathology.
Results: Out of 67 patients, 28 to 77 years of age (mean ± SD of 49.61 ± 11.572 years), 17.9% (12) patients had
T1tumour while 82.1% (55) had T2 tumour (mean ± SD of 3.48 cm ± 1.050 cm). Histopathology revealed no
metastasis in SLNs as well as ALN of 55.2% (37) patients while 40.3% (27) patients were positive for both.
However, in 4.5% (3) patients SLNs were negative for metastasis with positive ALN. Diagnostic accuracy was
calculated to be 95.5%, sensitivity 90%, false negative rate 4.5% and negative predictive value 92.5%.
Conclusion: Intraoperative radionuclide scintigraphy, using 99mTc-Nanocolloids and handheld gamma probe is
a reasonably accurate technique for localization of SLNs in early breast carcinoma.

Downloads

Download data is not yet available.

Downloads

Published

31-10-2018

Issue

Section

Original Articles

How to Cite

1.
Dar ZS, Aziz O bin A, Sajid T, Ali MK. ACCURACY OF INTRAOPERATIVE RADIONUCLIDE SCINTIGRAPHY FOR DETECTION OF SENTINEL LYMPH NODE USING 99MTC LABELED NANOCOLLOIDS IN EARLY BREAST CARCINOMA: Intraoperative Radionuclide Scintigraphy. Pak Armed Forces Med J [Internet]. 2018 Oct. 31 [cited 2024 Dec. 23];68(5):1101-5. Available from: https://pafmj.org/PAFMJ/article/view/2263