VALIDATION OF DIAGNOSTIC ACCURACY OF LEADS AVR AND V1 IN ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA (AVNRT)

Authors

  • Muhammad Shabbir Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Muhammad Irfan Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Maham Zahid Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Azmat Hayat Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Waheed Ur Rehman Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Syed Muhammad Imran Majeed Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi

Keywords:

Atrioventricular nodal reentrant tachycardia (AVNRT), supraventricular tachycardia, QRS complex

Abstract

Objective: To evaluate specificity, sensitivity and diagnostic accuracy of r’ deflection at the end of the QRS complex in leads aVR and V1 of ECG for diagnosis of AVNRT

Study Design: Descriptive cross sectional study.

Place and Duration of Study: This study was conducted at AFIC/NIHD Rawalpindi from Nov 2014 to Jan 2015.

Material and Methods: Sixty two patients presenting to AFIC/NIHD for catheter ablation from November 2014 to January 2015 were enrolled in the study. The ECGs were evaluated for r’ deflection in leads V1, AVR and pseudo S wave in the inferior leads prior to performing an electrophysiology study. The diagnosis was confirmed by cardiac electrophysiology study.

Results: The AVNRT was correctly diagnosed in 88.5% of cases. For AVNRT diagnosis, r’ deflection in AVR (sensitivity 90.1%, specificity 100%), r’ deflection in V1 (sensitivity 90.1%, specificity 100%) and pseudo S wave (sensitivity 86.6%, specificity 100%) predicted AVNRT in 93%, 91% and 85% of cases, respectively. Therefore the presence of r’ deflection in V1 and aVR leads; and pseudo S wave in the inferior leads were found to be reliable predictors of AVNRT.

Conclusion: The standard ECG criterion of pseudo r’ deflection and pseudo S wave is an accurate method of diagnosing AVNRT.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

31-03-2015

How to Cite

Shabbir, M., Irfan, M., Zahid, M., Hayat, A., Rehman, W. U., & Majeed, S. M. I. (2015). VALIDATION OF DIAGNOSTIC ACCURACY OF LEADS AVR AND V1 IN ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA (AVNRT). Pakistan Armed Forces Medical Journal, 65((SUPPL), S86–9. Retrieved from https://pafmj.org/PAFMJ/article/view/4419