VALIDATION OF DIAGNOSTIC ACCURACY OF LEADS AVR AND V1 IN ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA (AVNRT)

Authors

  • Muhammad Shabbir Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Muhammad Irfan Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Maham Zahid Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Azmat Hayat Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Waheed Ur Rehman Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi
  • Syed Muhammad Imran Majeed Armed Forces Institute of Cardiology and National Institute of Heart diseases, Rawalpindi

Keywords:

Atrioventricular nodal reentrant tachycardia (AVNRT), supraventricular tachycardia, QRS complex

Abstract

Objective: To evaluate specificity, sensitivity and diagnostic accuracy of r’ deflection at the end of the QRS complex in leads aVR and V1 of ECG for diagnosis of AVNRT

Study Design: Descriptive cross sectional study.

Place and Duration of Study: This study was conducted at AFIC/NIHD Rawalpindi from Nov 2014 to Jan 2015.

Material and Methods: Sixty two patients presenting to AFIC/NIHD for catheter ablation from November 2014 to January 2015 were enrolled in the study. The ECGs were evaluated for r’ deflection in leads V1, AVR and pseudo S wave in the inferior leads prior to performing an electrophysiology study. The diagnosis was confirmed by cardiac electrophysiology study.

Results: The AVNRT was correctly diagnosed in 88.5% of cases. For AVNRT diagnosis, r’ deflection in AVR (sensitivity 90.1%, specificity 100%), r’ deflection in V1 (sensitivity 90.1%, specificity 100%) and pseudo S wave (sensitivity 86.6%, specificity 100%) predicted AVNRT in 93%, 91% and 85% of cases, respectively. Therefore the presence of r’ deflection in V1 and aVR leads; and pseudo S wave in the inferior leads were found to be reliable predictors of AVNRT.

Conclusion: The standard ECG criterion of pseudo r’ deflection and pseudo S wave is an accurate method of diagnosing AVNRT.

Downloads

Download data is not yet available.

Downloads

Published

31-03-2015

How to Cite

1.
Shabbir M, Irfan M, Zahid M, Hayat A, Rehman WU, Majeed SMI. VALIDATION OF DIAGNOSTIC ACCURACY OF LEADS AVR AND V1 IN ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA (AVNRT). Pak Armed Forces Med J [Internet]. 2015 Mar. 31 [cited 2025 Mar. 12];65((SUPPL):S86-9. Available from: https://pafmj.org/PAFMJ/article/view/4419