Comparison of Effects of LED Phototherapy with Compact Fluorescent Phototherapy in Neonates with Hyperbilirubinemia

Authors

  • Amna Saleem Pakistan Railway Hospital, Rawalpindi Pakistan
  • Bilal Ahmed Pakistan Railway Hospital, Rawalpindi Pakistan
  • Sajid Ali Shah National University of Medical Sciences(NUMS) Rawalpindi Pakistan
  • Fahim Ahmed Subhani Pakistan Railway Hospital, Rawalpindi Pakistan
  • Ammara Ayub Pakistan Railway Hospital, Rawalpindi Pakistan
  • Saba Afzal Shiekh Pakistan Railway Hospital, Rawalpindi Pakistan

DOI:

https://doi.org/10.51253/pafmj.v73i2.6824

Keywords:

Bilirubin level, Compact fluorescent lamp phototherapy, Light emitting diode phototherapy, Hyperbilirubinemia, Neonate

Abstract

Objective: To compare the mean post-treatment bilirubin level with light emitting diode (LED) phototherapy versus compact fluorescent lamp (CFL) phototherapy in neonates presenting with hyperbilirubinemia

Study Design: Comparative prospective study

Place and Duration of Study: Department of Paediatrics, Pakistan Railway Hospital, Rawalpindi Pakistan, from Jan to Dec 2019.

Methodology: Hundred children fulfilling the inclusion criteria were recuited in the study from Emergency Department. Then neonates were divided into two groups. In Group-A, neonates underwent phototherapy with LED; in Group-B, neonates underwent phototherapy with conventional phototherapy. Then neonates were followed up in the neonatal intensive care unit for 24 hours. Pre and post-treatment reports were assessed, and bilirubin level was noted.

Results: In Group-A, the mean age of neonates was 49.12±23.42 hours, while in Group-B was 38.70±15.42 hours. In Group-A, the mean Bilirubin level at baseline was 13.64±5.98 gm/dl and in Group-B was 15.88±5.44 gm/dl. In Group-A, the mean Bilirubin level after 24 hours was 8.47±4.96 gm/dl and in Group-B was 9.538±5.35 gm/dl. In both groups, no significant difference in the mean bilirubin level was observed after 24 hours (p-value=0.30).

Conclusion: Light-emitting diode phototherapy and compact fluorescent lamp phototherapy are equally effective in a mean reduction in the total serum bilirubin after 24 hours.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

14-04-2023

How to Cite

1.
Saleem A, Ahmed B, Shah SA, Subhani FA, Ayub A, Shiekh SA. Comparison of Effects of LED Phototherapy with Compact Fluorescent Phototherapy in Neonates with Hyperbilirubinemia. Pak Armed Forces Med J [Internet]. 2023 Apr. 14 [cited 2024 May 21];73(2):337-40. Available from: https://pafmj.org/PAFMJ/article/view/6824

Issue

Section

Original Articles

Most read articles by the same author(s)

<< < 1 2 3 4 5 > >>