Comparison of the Diagnostic Accuracy of Doppler Cerebroplacental Ratio Versus Standard Fetal Biometry for Fetal Growth Restriction

Authors

  • Sadaf Aziz Combined Military Hospital, Multan/National University of Medical Sciences (NUMS) Pakistan
  • Pareesae Humayun Combined Military Hospital, Multan/National University of Medical Sciences (NUMS) Pakistan
  • Mariam Altaf Combined Military Hospital, Multan/National University of Medical Sciences (NUMS) Pakistan
  • Yasser Khan Combined Military Hospital, Multan/National University of Medical Sciences (NUMS) Pakistan
  • Syed Atif Hussain Andrabi Combined Military Hospital, Multan/National University of Medical Sciences (NUMS) Pakistan
  • Mubashrah Aziz Combined Military Hospital, Multan/National University of Medical Sciences (NUMS) Pakistan

DOI:

https://doi.org/10.51253/pafmj.v73i2.8389

Keywords:

Cerebroplacental ratio, Doppler ultrasound, Fetal growth restriction, Sensitivity

Abstract

Objective: To assess the diagnostic accuracy of the Doppler Cerebroplacental ratio for fetal growth restriction keeping fetal biometry as the reference standard.

Study Design: Cross-sectional study.

Place and Duration of Study: Department of Radiology, Combined Military Hospital, Multan Pakistan, from May to Oct 2020.

Methodology: Two hundred and fifty-six-singleton pregnancies ≥ 30 weeks were included and underwent fetal biometry, including estimated fetal weight (EFW) by trans-abdominal ultrasound. The umbilical artery and middle cerebral artery resistive indices were evaluated using Doppler ultrasound, and Cerebroplacental ratio (CPR) was calculated. The presence or absence of fetal growth restriction (FGR) was noted using cut-off EFW of 10th centile and CPR of 1.0.

Results: Cerebroplacental ratio showed FGR in 145(56.64%) patients. Fetal biometry showed FGR in 141 (55.08%) patients,whereas 115(44.92%) patients revealed none. Of 145 CPR-positive patients, 127(87%) were true positive, while 18(12%) were false positive. Among 111 CPR-negative patients, 14(0.12%) were false negative, while 97(87%) were true negative. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of the Cerebroplacental ratio were 90.07%, 84.35%, 87.59%, 87.39% and 87.50%, respectively.

Conclusions: Doppler Cerebroplacental ratio is sensitive for diagnosing fetal growth restriction; however, its role as a stand alone test needs further evaluation and may be enhanced with other tools such as estimated fetal weight.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

18-04-2023

How to Cite

Aziz, S., Humayun, P., Altaf, M., Khan, Y., Andrabi, S. A. H., & Aziz, M. (2023). Comparison of the Diagnostic Accuracy of Doppler Cerebroplacental Ratio Versus Standard Fetal Biometry for Fetal Growth Restriction. Pakistan Armed Forces Medical Journal, 73(2), 414–17. https://doi.org/10.51253/pafmj.v73i2.8389

Issue

Section

Original Articles

Most read articles by the same author(s)

1 2 > >>