CARDIOVASCULAR RESPONSE TO LARYNGOSCOPY VERSUS FIBER-OPTIC BRONCHOSCOPE DURING OROTRACHEAL INTUBATION IN PATIENTS UNDERGOING ELECTIVE SURGERY

Authors

  • Moazzam Ali 130 Medical Battalion/National University of Medical Sciences (NUMS) Pakistan
  • Maliha Khawar Pak Emirates Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
  • Maryam Nazneen Combined Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
  • Zaqawat Nazneen 05 Medical Battalion/National University of Medical Sciences (NUMS) Pakistan

DOI:

https://doi.org/10.51253/pafmj.v71iSuppl-1.2544

Keywords:

fiber optic bronchoscope, hemodynamics, intubation, laryngoscopy, stress response

Abstract

Objective: To compare the hemodynamic response between flexible fiber optic bronchoscope (FOB) and
Macintosh laryngoscope during orotracheal intubation. The secondary objective was to calculate the time
required for intubation between these two techniques

Study Design: Quasi experimental study.

Place and Duration of Study: Department of Anesthesia, Frontier Corps Hospital Quetta, from Oct 2016 to Apr
2017.

Methodology: Eighty patients fulfilling the inclusion/exclusion criteria were included in this study and were
divided randomly into two groups. Group L was intubated with Macintosh laryngoscope (control group) whereas group F was intubated with Fiber optic bronchoscope. Mean arterial pressure and heart rate was recorded as baseline, pre-intubation and then every 01 minute for 03 minutes. Changes in heart rate and mean arterial pressure were recorded in the proforma by another anesthetist who was blinded to the procedure performed.

Results: The mean age in group L was 41.23 ± 8.37 years and in group F was 40.73 ± 9.77 years. The mean weight in group L was 69.63 ± 8.92 kg and in group F was 70.6 ± 9.20 kg. In group L, male to female ratio was 26:14 whereas in group F it was 28:12. Mean heart rate and mean arterial pressure did not show significant change over time between groups. Time required for intubation was significantly less (22.45 ± 4.12 secs) in laryngoscopy group versus Fiber-Optic Bronchoscope group (44.68 ± 5.88 secs).

Conclusion: In conclusion we can say that our study demonstrated that using laryngoscope or Fiber-Optic
Bronchoscope for orotracheal..........

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

28-01-2021

How to Cite

Ali, M., Khawar, M., Nazneen, M., & Nazneen, Z. (2021). CARDIOVASCULAR RESPONSE TO LARYNGOSCOPY VERSUS FIBER-OPTIC BRONCHOSCOPE DURING OROTRACHEAL INTUBATION IN PATIENTS UNDERGOING ELECTIVE SURGERY. Pakistan Armed Forces Medical Journal, 71(Suppl-1), S180–85. https://doi.org/10.51253/pafmj.v71iSuppl-1.2544