Renal Artery Doppler as Screening Imaging Modality Required for theEvaluation of Hypertension in Cardiac Patients Experience at Tertiary Cardiac Care Centre

Authors

  • Afshan Israr Islamabad Diagnostics Centre, Peshawa
  • Nazia Dildar Combined Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
  • Sadia Azmat Islamabad Diagnostics Centre, Rawalpindi Pakistan
  • Sara Khan Armed Forces Institute of Radiology & Imaging/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
  • Farrukh Nadeem Combined Military Hospital, Lahore/National University of Medical Sciences (NUMS) Pakistan
  • Sehrish Shawrez Khan Islamabad Diagnostics Centre, Rawalpindi Pakistan

DOI:

https://doi.org/10.51253/pafmj.v72iSUPPL-3.9538

Keywords:

Angiography, Hypertension, Renal artery doppler

Abstract

Objective: To evaluate the efficiency of renal artery Doppler in diagnosis of secondary hypertension among cardiac patients.

Study Design: Analytical Cross-sectional study.

Place and Duration of Study: The present study was performed at Tertiary Care Center, Rawalpindi from Jan 2019 to July
2019.

Methodology: The study comprised of 50 patients with age range of 12-75 years with 90% confidence interval and 10% margin of error with prevalence of hypertension in Pakistan as 26.34%12. The study population included hypertensive patients referred for Doppler assessment of renal artery stenosis (RAS), in order to assess secondary cause of hypertension. The patients underwent angiography of kidneys within 14 days following Doppler assessment of RAS. The positive and negative outcome was presented as frequencies and percentages. The mean age was depicted as means ± standard deviation. The diagnostic features of specificity, sensitivity, negative predictive value and positive predictive values were calculated through a 2x2 table with angiographic findings considered as gold standard.

Results: In only 4(8%) patients bilaterally raised resistive index (RI) were evident. The diagnostic attributes of Doppler showed sensitivity of 48%, positive predictive value of 100% and diagnostic accuracy of 48%.

Conclusion: The role of renal artery Doppler in evaluating secondary hypertension has been over estimated. Thus, its
application needs to be restricted for elderly patients to minimize time and cost expenses.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

22-11-2022

How to Cite

Israr, A., Dildar, N., Azmat, S., Khan, S., Nadeem, F., & Khan, S. S. (2022). Renal Artery Doppler as Screening Imaging Modality Required for theEvaluation of Hypertension in Cardiac Patients Experience at Tertiary Cardiac Care Centre. Pakistan Armed Forces Medical Journal, 72(SUPPL-3), S482–85. https://doi.org/10.51253/pafmj.v72iSUPPL-3.9538