Abstract

Objective: To validate ‘stress only’ protocol against ‘rest stress protocol in normal and essentially normal cases undergoing Tc99m MIBI gated myocardial perfusion Single Photon Emission Computed Tomography imaging.

Study Design: A retrospective observational study.

Place and Duration of Study: Department of Nuclear Cardiology, Armed Forces Institute of Cardiology/National Institute of Heart Disease, Rawalpindi, Pakistan, from Jul to Sep 2019.

Methodology: 136 cases were included. Patients underwent Tc-99m gated Single Photon Emission Computed Tomography MPI using a single day, rest/stress protocol. The rest study was performed first with 8-10 mCi Tc-99m MIBI followed by stress study, 3 hours later with 3 times the rest dose. The most common stress technique was pharmacological stress and bicycle ergometer exercise with 0.14 mg/kg/min adenosine infusion. Few patients underwent physical stress using Bruce protocol, achieving a minimum of 85% of the target heart rate. Mages–stress followed by rest–were evaluated by two experienced nuclear cardiologists (blinded to the MPI reports) and interpreted as ‘normal’ or ‘essentially normal’.

Results: Evaluation of stress-only and rest-stress Single Photon Emission Computed Tomography myocardial images yielded a concordance rate of 84.56% with Cohen’s kappa coefficient of 0.69.

Conclusion: Substantial agreement and good concordance were found in normal and essentially normal ‘stress only’ and ‘rest stress protocols.

Downloads

Download data is not yet available.

Downloads

Published

31-10-2021

Issue

Section

Original Articles

How to Cite

1.
Dar ZS, Raza M, Atif M, Bukhari AR. TECHNETIUM-99M MIBI GATED MYOCARDIAL PERFUSION SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IMAGING – VALIDATION OF STRESS ONLY PROTOCOL. Pak Armed Forces Med J [Internet]. 2021 Oct. 31 [cited 2024 Nov. 23];71(5):1741-45. Available from: https://pafmj.org/PAFMJ/article/view/5391